RPB–200: RF Receiver
1530 Old Oakland Road, Suite 100 01825-200 Rev. B
San Jose, CA 95112 USA
(800) 260-5265 (408) 451-2520 FAX (408) 441-0309
Web: http://www.kerisys.com E-mail: [email protected] Page 2 of 8
Quick Start Guide
RPB–200
2.0 Connections
The connection between the PXL controller and the RPB-200 is made through a 7 conductor, shielded, stranded, AWG
24 wire cable (such as Belden 9537 or a larger gauge).
Before running a cable to the RPB-200 you must drill a 1/4 inch diameter hole in the case of the RPB-200 to
accommodate the cable. After the cable has been connected to the RPB-200, the cable/hole can be sealed with a
silicone/RTV type sealer.
2.1 Connecting to the RPB-200
The cable connects to the terminal strip on the RF receiver board, pins 1 through 8 (excluding pins 3 and 6). The cable
shield is not connected at the RPB-200.
2.2 Connecting to the PXL-250W
For an "A" reader connection, the cable connects to TB5 pins 1 through 7 (excluding pin 2). For a "B" reader
connection, the cable connects to TB6 pins 1 through 7 (excluding pin 2).
RPB–200 Cable Connections Connecting to the PXL–250W at TB5/TB6
Figure 2: RPB–200 Connections Figure 3: PXL–250W Connections
Pin # Function Wire Color Pin # Function Wire Color
1 Ground Black 4 Ground Black
––
4 Shield Silver
2Power Red
3 12V Power Red
3 no connection
2not used
4 Red LED Brown
6 Red LED Brown
5 Green LED Orange
5 Green LED Orange
6 Yellow LED
––
7 Data 1 White
7 Data 1 White
8 Data 0 Green
1 Data 0 Green